Pump Head Only, on Stand, or on Oil Filled Gearbox

For OEM applications -- choose pump only or with gear-box that keeps your drive from turning the pump faster than 200 RPM. Shaft is 1/2" diameter, extends 2" from pump or gearbox case.
Specify tubing material and ID.

MAXIMUM FLOW RATE BY TUBING SIZE
AT 200 RPM MAXIMUM PUMP SPEED
Gal./Hr. & CC/Min.
Model No. Gearbox Ratio Maximum Input RPM 1/8" ID 1/4" ID 3/8" ID 1/2" ID
410-000 None 200 5.1
320
19.1
1200
34.9
2200
57.1
3600
410-010 21/1 4200 5.1
320
19.1
1200
34.9
2200
57.1
3600
410-040 4.6/1 920 5.1
320
19.1
1200
34.9
2200
57.1
3600







HOW TO ORDER THE RIGHT TAT HIGH CAPACITY PUMP TO MEET YOUR SPECIFIC PUMPING NEEDS...
  • Specify Model Number: 110-030, 110-#3A, 110-43E, etc.
  • Specify Tubing Material: Neoprene, Hypalon, etc.
    NOTE: Choose proper Tubing material for fluid to be pumped using Chemical Resistance Chart.
  • Specify Motor Type for Fixed-Speed Electric Pumps by substituting 1, 2, or 3 for # sign (1 for open frame motor, 2 for totally enclosed motor, 3 for explosion-proof motor).
  • All Series 110 Pumps supplied with roller assembly adjustable for 3/32", 1/8", 5/32", and 3/16" tubing wall thickness.